New Victoria Theatre
Contact Information
Main Contact
01483 545855
Company Manager
Box Office
01483 545900
General Admin
01483 545855
Stage Door
01483 545855
Fax
Website
www.TheAmbassadors.com/Woking
Website Technical Page
Theatre Staff
Technical Manager
Chief Electrician
Mark Alington
Sound Technician
Stage Manager
Stage Carpenter
Flyman
Wardrobe Contact
FOH Contact/Manager
Accomodation list is available from
Stage door
Stage Details (all dimensions are in metres.)
Type of stage (pros, thrust etc)
End stage
Rake
No
Surface
Black
Is drilling or other fixing allowed?
Yes
Type of flying system
Counterweight
Total number of lines
60 = 4 up&down
Barrel (pipe) diameter
48mm
Barrel length
14m + extensions
Max load rating per set
500kg
Maximum out dead
20m
Overall load rating
Spacing between lines
200mm
Distance of first available set of lines from US side of pros
Apron Width
Apron Depth
Traps/Size
By arrangement
Weight Restrictions
Are stage plans available? If so, where from?
Modelbox
Stage Management facilities
Prompt corner pos.
PS
FOH call facilities?
Yes
Q-Lights?
Yes
Bar Bells?
Yes
Q-Lights Movable?
If REALLY necessary
First aid box?
Various
Overall Dimensions
Size of Prosc:
Width
Height
Wing Space:
Stage Left
Height of Grid
Stage Right
Setting line to rear of prosc
Setting line to front edge of stage
Setting line rear wall
Are these available?
House tabs
Yes
Cyc.
Yes
Blacks:
Borders
4
Legs
4 pairs
Tabs
1
Unusual or unexpected features
eg) Get in - height, drop, ramp etc...
LX & Sound Details
Power available and location:
Lighting
300A 3ph, Stg Rt
Sound
63A 1ph, either side
LX & Sound Details
Additional power supplies available:
32A 3ph, 63A 3 ph CEE-form, Up Stg
Lighting Control
Strand 550
Number of dimmers and ratings:
On stage
168 plus 24 non-dims
FOH
72
Any patching/twinning
All FOH can be patched
Lanterns available in fixed location:
Profiles
62
Fresnels
2
Cyc Floods
Follow Spots
2
Movable lanterns list
42 x fresnels 1k, 10 x fresnels 2k
40 x PAR 64
Cyc floods
Ground row / floats
40 x PAR 64
Cyc floods
Ground row / floats
Rigging (Tallescope/ladder etc)
2 x tallescope
Sound
Indication of tie lines
240 lines
Mixer position
Control room, opening window
Equipment available
CD, MD, SPX
Touring mixer posn in auditorium
Video tielines
Touring mixer posn in auditorium
Video tielines
Headset/comms details
TechPro, 2-ring, 6-pin
Accomodation
Dressing rooms
14 rooms
Showers & toilets
Yes
Access to stage
On 4 floors inc stage
Wardobe facilities
Yes
Wig room & facilities
Orchestra
Pit size (permanent or variable)
Adjustable lift, max capacity 64. Can be extended
Equipment Available
Lit music stands
No
Chairs
Yes
Net
No
Rostra
No
Double bass pin boards
No
Sound baffles
No
Orchestra Accomodation
Band Rooms
2
Other
Any other features
Auditorium reverb ACS system