Contact Information
Main Contact
020 7589 3203
Company Manager
Box Office
020 7589 8212
General Admin
020 7589 3203
Stage Door
020 7589 3203
Fax
020 7823 9784
Website
www.royalalberthall.com
Website Technical Page
Theatre Staff
Technical Manager
Chief Electrician
Mark Jones
Sound Technician
-
Stage Manager
Fiona Scott-Lockyer
Stage Carpenter
Jon Cox
Flyman
Ges Edwards-Webb
Wardrobe Contact
-
FOH Contact/Manager
Sarah Howarth
Accomodation list is available from
Jane Lee - Show Department administrator
Stage Details (all dimensions are in metres.)
Type of stage (pros, thrust etc)
Concert Platform
Rake
None
Surface
Hardboard on timber
Is drilling or other fixing allowed?
Yes - with permission
Type of flying system
Truss on chain hoists
Total number of lines
5 cross stage trusses
Barrel (pipe) diameter
GP truss
Barrel length
14m approx.
Max load rating per set
2.5 tonnes UDL
Maximum out dead
25m approx
Overall load rating
adequate
Spacing between lines
4m approx
Distance of first available set of lines from US side of pros
Apron Width
Apron Depth
Traps/Size
None
Weight Restrictions
Are stage plans available? If so, where from?
Yes
Technical Manager
Technical Manager
Stage Management facilities
Prompt corner pos.
SL or SR
FOH call facilities?
Yes
Q-Lights?
PA calls
Bar Bells?
No
Q-Lights Movable?
First aid box?
First Aid Room / Stage Door
Overall Dimensions
Size of Prosc:
Width
Stage approx 12m at narrowest
Height
0.95m
Wing Space:
Stage Left
None
Height of Grid
Min 30m
Stage Right
None
Setting line to rear of prosc
Setting line to front edge of stage
Setting line rear wall
Approx 12m
Are these available?
House tabs
N/A
Cyc.
No
Blacks:
Borders
No
Legs
No
Tabs
No
Unusual or unexpected features
eg) Get in - height, drop, ramp etc...
Underground access for 3 trucks, then via 5tonne lift
LX & Sound Details
Power available and location:
Lighting
1200A TPN
Sound
200A TPN
LX & Sound Details
Additional power supplies available:
some
Lighting Control
Jands Echelon
Number of dimmers and ratings:
On stage
125
FOH
125
Any patching/twinning
fully patchable
Lanterns available in fixed location:
Profiles
Source 4, various lenses
Fresnels
Par 64 & Source 4 pars. Total approx 150
Cyc Floods
None
Follow Spots
4 x 1.2kw HMI's
Movable lanterns list
8 x Stage Zooms 1200
Rigging (Tallescope/ladder etc)
Genie lift (ticket required)
Sound
Indication of tie lines
Mixer position
Usually rear arena
Equipment available
Small Meyer MSL3 centre cluster
Headset/comms details
ClearCom twin channel. 6 sets available
tie lines to all positions
tie lines to all positions
Accomodation
Dressing rooms
5 Principal, 7 chorus
Showers & toilets
Plenty
Access to stage
Same level L & R
Wardobe facilities
some, on request
Wig room & facilities
chorus dressing room
Orchestra
Pit size (permanent or variable)
N/A
Equipment Available
Lit music stands
None
Chairs
Plenty
Net
N/A
Rostra
By arrangement
Double bass pin boards
none
Sound baffles
none
Orchestra Accomodation
Band Rooms
see Chorus dressing rooms
Other
Any other features
Fully de-mountable stage risers
Arena space chaired or standing
Upright piano availble - No Grand
Arena space chaired or standing
Upright piano availble - No Grand