Snape Maltings Concert Hall
Contact Information
Address
Snape Maltings Concert Hall
Town
Snape
County
Suffolk
Postcode
IP17 1SP
Email
Main Contact
01728 687100
Company Manager
Box Office
01728 687110
General Admin
01728 687100
Stage Door
Fax
Website
www.aldeburgh.co.uk
Website Technical Page
Theatre Staff
Technical Manager
Ron Green
Chief Electrician
Geoff Spain
Sound Technician
Stage Manager
Stage Carpenter
Flyman
Wardrobe Contact
FOH Contact/Manager
Accomodation list is available from
Stage Details (all dimensions are in metres.)
Type of stage (pros, thrust etc)
Concert - hydraulic forestage/apron
Rake
Hydraulic - approx .25m
Surface
Hardwood
Is drilling or other fixing allowed?
No
Type of flying system
Winch
Total number of lines
5 powered LX. 7 handwinch
Barrel (pipe) diameter
50mm
Barrel length
14m
Max load rating per set
LX - 540kg handwinch - 200kg
Maximum out dead
approx 8m
Overall load rating
Spacing between lines
varies
Distance of first available set of lines from US side of pros
1m
Apron Width
8.9m - 13.2m
Apron Depth
2.7m
Traps/Size
1 approx 1.5m x 4m
Weight Restrictions
Are stage plans available? If so, where from?
Geoff Spain
Stage Management facilities
Prompt corner pos.
Control Rm, SR, SL
FOH call facilities?
Yes
Q-Lights?
No
Bar Bells?
Yes
Q-Lights Movable?
Yes
First aid box?
Yes
Overall Dimensions
Size of Prosc:
Width
No Prosc.
Height
Wing Space:
Stage Left
No Wings - scene dock
Height of Grid
Bars fly to approx 8m
Stage Right
No wings
Setting line to rear of prosc
Setting line to front edge of stage
Setting line rear wall
Are these available?
House tabs
No
Cyc.
No
Blacks:
Borders
No
Legs
Yes
Tabs
No
Unusual or unexpected features
eg) Get in - height, drop, ramp etc...
Stage dimensions - 17.88m (w) x 12.22m (h)Restricted access to stage max width 2.24m, max height 2.29mFront of stage height 1.17m
LX & Sound Details
Power available and location:
Lighting
200 amp 3 phase (bare ends)
Sound
60 amp 1 phase
LX & Sound Details
Additional power supplies available:
125 amp 3 phase Ceeform
Lighting Control
Rear auditorium
Number of dimmers and ratings:
On stage
approx 120
FOH
approx 80
Any patching/twinning
Yes
Lanterns available in fixed location:
Profiles
Fresnels
Cyc Floods
Follow Spots
Movable lanterns list
18 x 19 deg S4, 12 x 26 deg S4, 4 x 36 deg S4
10 x 15 - 30 deg S4
10 x 15 - 30 deg S4
Rigging (Tallescope/ladder etc)
Sound
Indication of tie lines
Mixer position
Equipment available
Headset/comms details
Accomodation
Dressing rooms
Showers & toilets
Access to stage
Wardobe facilities
Wig room & facilities
Orchestra
Pit size (permanent or variable)
Equipment Available
Lit music stands
Chairs
Net
Rostra
Double bass pin boards
Sound baffles
Orchestra Accomodation
Band Rooms
Other
Any other features
Change History: Authorised