Theatre Severn - Walker Theatre
Entry updated 16-Mar-2010
Contact Information
Main Contact
Company Manager
Box Office
01743 281 281
General Admin
Stage Door
Fax
Website
www.theatresevern.co.uk
Website Technical Page
Theatre Staff
Technical Manager
Grant Wilson - 01743 256 515
Chief Electrician
Sound Technician
Stage Manager
Kath Brown - 01743 256 516
Stage Carpenter
Flyman
Wardrobe Contact
FOH Contact/Manager
David Jack - 01743 256 502
Accomodation list is available from
Stage Details (all dimensions are in metres.)
Type of stage (pros, thrust etc)
Flat floor removeable raked seating.
Rake
no
Surface
Dark Grey Painted Hardboard
Is drilling or other fixing allowed?
No fixings larger than ordinary screws
Type of flying system
Counterweight
Total number of lines
27
Barrel (pipe) diameter
48mm
Barrel length
10m
Max load rating per set
300kg
Maximum out dead
11.5m
Overall load rating
Spacing between lines
300mm centres
Distance of first available set of lines from US side of pros
900mm
Apron Width
Apron Depth
Traps/Size
Weight Restrictions
Are stage plans available? If so, where from?
Stage Management facilities
Prompt corner pos.
Default USL - moveable
FOH call facilities?
Yes
Q-Lights?
Yes
Bar Bells?
Yes
Q-Lights Movable?
Yes
First aid box?
Yes
Overall Dimensions
Size of Prosc:
Width
Default 10m - variable
Height
6.5m
Wing Space:
Stage Left
1.5m
Height of Grid
12m
Stage Right
1.5m
Setting line to rear of prosc
n/a
Setting line to front edge of stage
n/a
Setting line rear wall
9m
Are these available?
House tabs
Yes - Purple & Gold
Cyc.
Yes
Blacks:
Borders
Legs
Tabs
Unusual or unexpected features
eg) Get in - height, drop, ramp etc...
Stage is on first floor access via large (2mx5m) platform lift
LX & Sound Details
Power available and location:
Lighting
Sound
LX & Sound Details
Additional power supplies available:
125a 3ph ceeform & 63a 1ph ceeform
Lighting Control
ETC Congo
Number of dimmers and ratings:
On stage
overall 156x3k, 12 x 5k , n/d
FOH
Any patching/twinning
Lanterns available in fixed location:
Profiles
Fresnels
Cyc Floods
Follow Spots
Movable lanterns list
Selection of Strand Fresnel&PC 1K, Source four profiles, thomas parcan 1k, Linear floods 1k.
Rigging (Tallescope/ladder etc)
Tallescope and Zrages Ladders
Sound
Indication of tie lines
Mixer position
Central rear auditorium
Equipment available
selection microphones, analogue or digital desk.
Headset/comms details
Techpro dual circuit
Accomodation
Dressing rooms
4 - Capacity 30-50 people
Showers & toilets
Male/female/accessible
Access to stage
Flat
Wardobe facilities
Wig room & facilities
Orchestra
Pit size (permanent or variable)
n/a
Equipment Available
Lit music stands
Available on request
Chairs
yes
Net
no
Rostra
Yes
Double bass pin boards
no
Sound baffles
no
Orchestra Accomodation
Band Rooms
Other
Any other features
Change History: Entry created 16-Mar-2010, Entry updated 16-Mar-2010, Entry updated 16-Mar-2010, Entry updated 16-Mar-2010, Entry updated 16-Mar-2010