Bonington Theatre
Contact Information
Address
High Str, Arnold
Town
Nottingham
County
Nottinghamshire
Postcode
NG5 7EE
Email
Main Contact
0115 9670114
Company Manager
Box Office
0115 9670114
General Admin
0115 9670114
Stage Door
0115 9670114
Fax
0115 9560731
Website
www.bonington-theatre.co.uk
Website Technical Page
Theatre Staff
Technical Manager
Bob Massey
Chief Electrician
Sound Technician
David Gotham
Stage Manager
Stage Carpenter
Flyman
Wardrobe Contact
FOH Contact/Manager
Sue Scott
Accomodation list is available from
Theatre and bonington web site
Stage Details (all dimensions are in metres.)
Type of stage (pros, thrust etc)
Pros or arena
Rake
no
Surface
wood block
Is drilling or other fixing allowed?
no
Type of flying system
hand line
Total number of lines
4
Barrel (pipe) diameter
37mm
Barrel length
7m
Max load rating per set
250kg/150kg
Maximum out dead
Overall load rating
Spacing between lines
2m
Distance of first available set of lines from US side of pros
2m
Apron Width
7m
Apron Depth
1m
Traps/Size
none
Weight Restrictions
Are stage plans available? If so, where from?
Bonington Theatre
or web site
or web site
Stage Management facilities
Prompt corner pos.
up stage left
FOH call facilities?
yes
Q-Lights?
talk
Bar Bells?
yes
Q-Lights Movable?
yes
First aid box?
yes
Overall Dimensions
Size of Prosc:
Width
7m
Height
5.5m
Wing Space:
Stage Left
1.5m/3m
Height of Grid
6m
Stage Right
1.5m
Setting line to rear of prosc
6m
Setting line to front edge of stage
1m
Setting line rear wall
7m
Are these available?
House tabs
yes
Cyc.
yes
Blacks:
Borders
yes
Legs
yes
Tabs
yes
Unusual or unexpected features
eg) Get in - height, drop, ramp etc...
first floor up straight stairs or small lift
LX & Sound Details
Power available and location:
Lighting
2 x100amp 3 phase ( on stage and control room)
Sound
26amp
LX & Sound Details
Additional power supplies available:
32 amp single phase on stage and control room
Lighting Control
72 way eclipse 500 mem and chase 6 dim ind
Number of dimmers and ratings:
On stage
24+4 dimmers
FOH
48
Any patching/twinning
all patched
Lanterns available in fixed location:
Profiles
25
Fresnels
40
Cyc Floods
9
Follow Spots
1
Movable lanterns list
3 floods 1kw and 6x 500w
4 x 1kw pc
14 x 650w fresnel
6 x patt23
4 x 1kw pc
14 x 650w fresnel
6 x patt23
Rigging (Tallescope/ladder etc)
tower
Sound
Indication of tie lines
10 mike 4 tie 4 fold back
Mixer position
control room or auditorium
Equipment available
10 mikes and stands
2 powered and 4 unpowered monitors
fixed foh speakers
2 powered and 4 unpowered monitors
fixed foh speakers
Headset/comms details
talk back via head sets x4 or fixed units to sm and control
Accomodation
Dressing rooms
2
Showers & toilets
2
Access to stage
spiral stairs
Wardobe facilities
washing machine
Wig room & facilities
no
Orchestra
Pit size (permanent or variable)
none
Equipment Available
Lit music stands
none
Chairs
100
Net
Rostra
1
Double bass pin boards
none
Sound baffles
none
Orchestra Accomodation
Band Rooms
extra room available by arrangement
Other
Any other features
stage is flat floor with raked seating. this is retractable and shows can be in round or club style with tables and chairs. seating in club style 120 or fixed seating 176
Change History: Authorised27-Sep-2004